OCPE Change Log

Version 2-3 - Release 15/04/2024

Special release during PlugFest 2024

  • Fixed issue with timers that locked the software into only working in the UTC time zone.
  • Fixed responses to ENDPOINT_RESPONSERS when Endpoint ID set to null.
  • Implemented Set SEARCH_DOMAIN.
  • Fixed bug with ACK_OVERFLOW
  • Set SCOPE now validates the length of the scope string to ensure it isn't null.

Version 2-2 - Release 15/04/2024

Special release at the start of PlugFest 2024

  • Added dialogue option to the RDM screen that allows responders to be added to multiple ports.
  • Fixed issues when there are more than 100 RDMnet devices.
  • Implemented ENDPOINT_TO_UNIVERSE and ENDPOINT_MODE for RPT Gateways.
  • Default IP address range for Art-Net nodes and RPT Gateways changed to 2.
  • Implemented firmware version field in ArtPollReply messages.
  • Improved how responders deal with SET_DEVICE_LABEL messages which are null or all white space characters.
  • Added duplicate packet check.
  • Added an Art-Net 4 version DE compliant device.

 


Version 2-1 - Release 24/09/2023

  • Fixed and issue with LLRP targets when the software is emulating a large number of targets.
  • LLRP counters are now displayed on the nodes screen.
  • Fixed an issue where fewer than requests nodes would be added to the nodes list when high volumes of network traffic were being received. 
  • Fixed issue with the component scope PID.
  • Improved UI Performance.
  • Implemented mDNS for RDMNet devices.
  • Settings screen now shows a warning colour when networking is disabled (yellow) and when the Pcap driver can not be found (red).

Version 2-0 - Release 01/09/2023

  • RDMNet support
    • RPT Gateways with 2/4/32 ports can be emulated.
    • LLRP targets for the RPT gateways. Only some of the allowed LLRP PIDs are currently supported.
    • RPT gateways only support conducting to brokers using an IPv4 static configuration. By default the gateways will try to connect to a broker at 10.0.0.1:49410.
  • Art-Net 
    • sACN can be received on dataLynx II when the port is in sACN mode.
  • General
    • Significant performance updates
    • IGMP v1 and v2 implementations for gateways

Version 1-5 - Release 26/02/2020

  • Added delayed transition gateways to developer edition.

Version 1-4 - Release 26/02/2020

  • Added slot information to moving head fixtures.
  • Added an LED Pixel Driver responder with 170 sub devices to the developer edition.
  • Added a responder with the maximum number of sub devices to the developer edition.
  • Bug fixes.

Version 1-2 - Release 22/12/2019

Added support for these PIDs:

  • Real time clock
  • Display level
  • Display invert
  • Maximum dimmer level
  • Minimum dimmer level
  • Burn in
  • Pan invert
  • Tilt invert
  • Pan/Tilt Swap

Version 1-1 - Release 20/12/2019

Network card library updated.


Version 0-12-2 - Release 03/12/2019

Further improvements to start-up sequence and error messages.
.Net Framework requirement reduced from 4.7.1 to 4.6.1.


Version 0-12-1 - Release 25/11/2019

Improved startup sequence and error messages.


Version 0-12-0 - Release 23/11/2019

First public release for Explorer only.